Pulling Shots
This will outline different methods to pull shots once the Slayer Mod has been performed.
Classic Slayer Shot
This mimics the typical shot that would be pulled on an actual Slayer
Setup
- Set needle valve to barely open
- Place cup on scale under grouphead
- Hold single cup button to run pump
- Let pump run for 10 seconds
- Divide weight of water by 10 to get your flowrate in ml/s
- Adjust valve and rerun test until you get 1.4ml/s
- Make a mark on the machine so save this position
- Set preinfusion time to 0 seconds
The Pull
- Install portafilter
- Set valve to 1.4ml/s mark
- Press manual button to start shot
- Preinfuse for desired time
- Aim to start pressure ramp around 18s
- First drops should start around 20s
- Pressure should get to 9 bar at about 25s
- Open valve for desired amount of full flow time
- Aim for 2/3 of your total output weight
- Set valve back to 1.4ml/s mark
- Press manual button to stop the shot when target weight is reached (or a bit before)
Blooming Espresso Shot
This shot mimics the blooming espresso outlined in Scott Rao's blog post: https://www.scottrao.com/blog/2018/7/18/advanced-mode-on-the-de1
Setup
- Perform pump kill switch mod
- Find and mark 4ml/s point as above
- Find and mark 2.2ml/s point as above
- Set preinfusion time to 0 seconds
The Pull
- Install portafilter
- Set valve to 4ml/s mark
- Press manual button to start shot
- Preinfuse until pressure ramps to 4bar
- Use kill switch to turn off the pump
- Wait for 30 seconds
- Set valve to 2.2ml/s
- Turn pump back on
- Run shot to desired output weight
Normal shot
This is just a normal shot ¯\_(ツ)_/¯\
Setup
- Set preinfusion time to desired amount
The Pull
- Install portafilter
- Set valve wide open
- Press manual button to start shot
- Run shot to desired output weight